Type | carbon monoxide detector |
smoke detector | |
Application | indoor only |
Compatibility | Ajax Hub |
Ajax Hub Plus | |
Ajax Hub 2 | |
Ajax ReX | |
Ajax Hub 2 Plus | |
Hub Hybrid | |
Ajax ReX 2 | |
Radio protocol | Jeweller |
Radio frequency | 868,0−868,6 MHz |
868,7−869,2 MHz | |
866,0 – 866,5 МГц | |
905,0 – 926,5 МГц | |
915,85 – 926,5 МГц | |
921,0 – 922,0 МГц | |
Power supply | batteries /2 батареї CR2 3 В, додаткова батарея СR2032 |
Type | carbon monoxide detector |
smoke detector | |
Application | indoor only |
Compatibility | Ajax Hub |
Ajax Hub Plus | |
Ajax Hub 2 | |
Ajax ReX | |
Ajax Hub 2 Plus | |
Hub Hybrid | |
Ajax ReX 2 | |
Radio protocol | Jeweller |
Radio frequency | 868,0−868,6 MHz |
868,7−869,2 MHz | |
866,0 – 866,5 МГц | |
905,0 – 926,5 МГц | |
915,85 – 926,5 МГц | |
921,0 – 922,0 МГц | |
Alarm response times on default settings | 0.15 sec |
Alarm volume | 85 Db |
Wireless transmission range | 1300 m (на відкритому просторі) |
Power supply | batteries /2 батареї CR2 3 В, додаткова батарея СR2032 |
Sensitive element | photoelectric sensor |
температурный сенсор | |
Battery life | 4 years |
Operating humidity | up to 80% |
Operating temperature | 0 ... +65 °C |
Radio signal power | 20 mW |
Additional information | multi-sensor synchronous alarm |
light and sound alert | |
защита от подмены | |
сообщение о глушении | |
тампер на открывание и отрывание | |
фильтр ложных тревог | |
Package Contents | detector |
CR2032 battery /(попередньо встановлена) | |
SmartBracket mounting panel | |
mounting kit | |
инструкция | |
2 батареи CR2 /(попередньо встановлені) |
Working distance in open space | 1300 m /між датчиком і централлю |
Dimensions | 132х132x31 mm |
Colour | white |
Weight | 220 g |
Zəmanət | 24 ay |
Principle of operation
The device detects smoke by means of a camera with a photoelectric sensor. An additional chemical element detects carbon oxide and raises the alarm.
Features of the detector
It can operate independently from the hub, emitting a fire alarm by means of a built-in siren. Several detectors indicate an alarm simultaneously.
Ready to operate straight out the box: the battery is already installed, therefore there is no need to disassemble the detector. With one click, it can be connected to the hub in the mobile application. It can be mounted on the SmartBracket in just a few minutes.
Fire Protection Plus - fire detector with temperature and carbon monoxide sensor
Fire detectors are needed for a full-fledged burglar alarm — devices that, even in the early stages of fire and smoke, report an incident. Smoke and gas detectors will help prevent severe consequences of a fire in a room and damage to property.
Ajax FireProtect Plus Wireless Fire Detector
FireProtect Plus is a wireless indoor fire detector equipped with a siren. The device works up to four years from a pre-installed battery. FireProtect Plus detects the presence of smoke in the room or a sharp increase in temperature and reacts to dangerous levels of carbon monoxide. The FireProtect Plus smoke detector works both as part of an intruder alarm system connected to the security system's control panel — hub and stand-alone.When used independently, in the event of fire detection, the sensor will report an alarm with a sound signal and the light turning on the logo. The FireProtect Plus wireless fire detector is connected to the Ajax security system via the Jeweller secure radio protocol and can operate at a distance of up to 1300 m from the hub in the absence of obstacles.
Principle of operation
The sensor detects smoke using an infrared emitter and a photodetector located in the smoke chamber. When smoke enters the camera, the photodetector detects it by the distortion of the infrared beam. Since some materials burn without emitting smoke, the fire alarm sensor detects sudden temperature changes. In the event of a fire, the gas sensor will turn on the siren with a volume of 85 dB, and the logo at this moment will turn red to indicate the incident. Users can turn off the triggered sensor siren by holding the Ajax logo on the device body for three seconds or through the Ajax application. If the smoke level or temperature does not return to normal after 10 minutes, the detector will turn on the siren again. In the event of an alarm, the security system notifies all users with sirens and push notifications, SMS, and calls — the type of notification depends on the settings. And the synchronous alarm function turns on the sirens of all fire detectors in the system as soon as one of them registers an alarm.
Features of the FireProtect Plus wireless fire detector:
The fire and smoke detector is designed for installation in any room with a risk of fire — shops, private premises, educational institutions, hotels, etc.
Complete set of fire detector FireProtect Plus:
Installation and connection of the Ajax FireProtect Plus wireless fire detector
The FireProtect Plus fire detection sensor connects to the hub in the mobile app. It is mounted on the SmartBracket mount and does not require disassembly of the case. When installing the Ajax security system, it is necessary to ensure the good audibility of fire detector sirens. The LED indication of the devices should be visible. It is recommended to install the FireProtect Plus smoke detector on the ceiling. The sensors will detect smoke and temperature fluctuations less effectively when placed on a wall. It is not recommended to install a fire detector:
To add a smoke detector to the Ajax system, you need to do the following:
If several FireProtect Plus sensors are used in the integrated security system, users can activate the synchronous alarm of fire sensors in the hub settings. This function turns on the built-in sirens of all fire detectors as soon as at least one of them registers an alarm. It is recommended to install a fire detector in all rooms where a fire can occur or carbon monoxide is allowed to form.
Conclusions
A complete security system should protect various factors, including fire and carbon monoxide leaks. FireProtect Plus can work both in the Ajax security system from the hub and stand-alone, signalling an alarm with a built-in siren. The fire alarm detects smoke using a photoelectric sensor. The fire detector is recommended to be installed in private premises and public places.